FISHTRO | Korean Indian Collaboration Technology • Make in IndiaISO Certified Assay
✦ The Scientific Edge in Bullion & Jewelry Assaying

Why Bullion Refiners & Jewelers Trust Fishtro KaratVision

Traditional acid checks and basic density methods fail against sophisticated multi-layer electroplating and toxic PGM adulterants. Fishtro combines precision Korean X-ray sensor architecture with localized Indian hardware resilience (`CFAN Technology`) to deliver non-destructive, certified assays in seconds.

8–15s Ultra-Fast Assay Speed
<118 eV FWHM Energy Resolution
<100 ppm Trace Adulterant Separation
100% BIS IS 1418 Compliant

Real Engineering & Analytical Advantages

Every KaratVision spectrometer (`K2, K3, K4, K5 Series`) is built with verified technical specifications extracted verbatim from official diagnostic sheets, eliminating guesswork and costly assay errors.

Peltier-Cooled Fast SDD Technology

Unlike outdated Si-PIN systems or liquid-nitrogen cooled detectors, our advanced Fast Silicon Drift Detectors (`FSDD`) operate with thermoelectric Peltier cooling. This achieves state-of-the-art energy resolution (`<118 eV to <145 eV @ 5.9 keV`), enabling count rates up to 1,000,000 cps without thermal drift.

✦ Specification: K3, K4 & K5 Series
🔬

Instant PGM & Kachra Adulterant Separation

Bullion fraud often involves alloying gold with trace Iridium (`Ir`), Osmium (`Os`), Ruthenium (`Ru`), or Tungsten (`W`), which mimic gold's density. KaratVision algorithms perform automatic quantitative separation of trace PGM adulterants down to `<100 ppm` instantly during standard testing.

✦ Specification: <100 ppm to <200 ppm Trace Detection
🎛️

Multi-Layer Plating & Vermeil Depth (`IS 2112`)

Accurately estimate up to 5 overlapping electroplated metal layers without scratching, filing, or acid etching. Verify top gold flash (`Au 99.9%`), nickel barrier substrates (`Ni 0.50 µm`), and base sterling silver (`Ag 92.5%`) down to `0.01 µm` depth capability.

✦ Specification: IS 2112 Plating Compliance
🎯

Motorized Multi-Pinhole Collimator Architecture

Testing tiny filigree wires, soldered earring posts, and micro-prongs requires pinpoint X-ray isolation. Our dual and quad motorized collimators (`0.1 / 0.3 / 1.0 / 3.0 mm`) paired with 20X/40X HD Macro cameras ensure the X-ray beam hits only the intended sample spot.

✦ Specification: 20X Zoom Alignment & Auto-Focus
🏛️

BIS Hallmarking (`IS 1418`) Certified Profiles

Designed specifically for Indian Assaying & Hallmarking Centers (`AHC`), bullion mandis, and retail showrooms. Pre-loaded Fundamental Parameters (`FP`) and empirical curves verify exact karatage (`24K, 22K, 18K, 14K`) strictly conforming to BIS `IS 1418` national standards.

✦ Specification: National Hallmarking Grade
🛡️

Heavy-Duty Indian Operating Resilience

Indian jewelry markets demand rugged continuous operation under elevated temperatures and power fluctuations. Powered by a Micro-Focus Tungsten tube (`50 kV / 100W`), our solid-state metallic chassis provides superior electromagnetic shielding and 24/7 reliability.

✦ Specification: 110-240V AC • 100W Low Power

Korean Analytical Science • Made in India Reliability

Fishtro Instruments unites high-precision Korean X-ray sensor hardware (`CFAN Instrument collaboration`) with robust Indian manufacturing and direct factory calibration support. This dual synergy guarantees uncompromised analytical speed alongside responsive, local technical service.

  • Direct Factory Calibration & Software Updates Periodic FP profile tuning and custom alloy calibration without expensive foreign shipping delays.
  • REACH Allergen & Hazardous Screening (`Pb, Cd, Ni`) Simultaneously screen jewelry items for toxic heavy metals to satisfy European and American export regulations.
  • Non-Destructive Testing (`NDT`) for High Valuation Zero loss of precious gold or silver dust during assaying, maximizing daily bullion profit margins.

Hardware & System Matrix

Detector Core Silicon Drift (SDD / FSDD / Si-PIN)
X-Ray Excitation Tube Micro-Focus Tungsten • 50 kV / 100W
Element Detection Range S (16) / Al (13) / Na (11) to U (92)
Collimator Options Fixed 1.0 mm or Motorized Multi-Pinhole
Chamber Geometry Bottom-to-Top • 30 kg Approx Chassis

How KaratVision Outperforms Traditional Assaying

See why modern bullion refiners, jewelry manufacturers, and national assay labs are upgrading from acid testing and first-generation benchtop devices.

Analytical Capability Traditional Acid / Touchstone First-Gen Si-PIN Analyzers Fishtro KaratVision (SDD / FSDD)
Assay Speed per Sample 3 – 5 Minutes (Manual & Slow) 60 – 120 Seconds ⚡ 8 – 15 Seconds (Instant Output)
Sample Damage (`NDT`) Destructive (Scraping & Acid Etching) Non-Destructive ✓ 100% Non-Destructive Zero Loss
PGM Adulterant Separation (`Ir, Os, Ru, W`) Cannot Detect (High Fraud Risk) Basic Warning Flags Only ✓ Automatic Quantitative Separation (<100 ppm)
Multi-Layer Plating & Vermeil Depth Impossible to Measure Layers Single Gold Flash Estimator ✓ Up to 5 Overlapping Layers (0.01 µm Depth)
Detector Cooling & Resolution N/A (Chemical Reaction) <180 eV (Basic Resolution) ✓ Peltier-Cooled <118 eV – <145 eV FWHM
Targeting & Spot Alignment Visual Guesswork Fixed Camera or No Zoom ✓ 20X / 40X HD Macro Zoom + Quad Pinholes
BIS `IS 1418` / Export Certification Subjective & Uncertified Basic Compliance Estimator ✓ Certified Hallmarking & Mint Lab Grade